Description
Metal Clad Armored Cable, Trade Designation MC, Wire Size 14 AWG, Number of Conductors 4 with Insulated CU Ground, Wire Color Black/Blue/Green/Red/White, Jacket Color Silver, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material Nylon, PVC, Nominal Outside Dia. 0.494 in, Packaging Coil, Voltage 600 V, Temp. Rating -14 Degrees to 90 Degrees C Dry
Specifications
Application | Indoor |
---|---|
Applications | ApplicationSouthwire Armorliteî Type MC Cable is suitable for use as follows:Branch, feeder and service power distribution in commercial, industrial, institutional, and multiresidential buildings.Fished or embedded in plaster.Concealed or exposed installationsEnvironmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations. |
Cable Type Wire and Cable | MC |
Conductor Design | Solid |
Construction | ConstructionSouthwire Armorliteî Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90ðC dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. |
Insulation Material | Nylon, PVC |
Insulation Thickness Mils | 15mils |
Item | Metal Clad Armored Cable |
Jacket Color | Silver |
Jacket Material | Aluminum |
Jacket Material Wire and Cable | Aluminum |
Length | 250 ft |
Length Straight Wireway | 250 ft |
Max Amps | 15 |
No of Conductors | 4 |
No of Strands | 1 |
Nom Od Mils | 508mils |
Nominal Outside Dia | 0.494 in |
Number of Conductors | 4 with Ground |
Packaging | Coil |
Size Awg | 14 |
Size Awg or Kcmil | 14 AWG |
Spool Length | 250 ft. |
Standards | UL 83, 1569, 1685, NEC Article 330, Federal Specification A-A59544 (Formerly J-C-30B), FT4/IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2 and 3 Hour Through Penetration Firestop Systems |
Stranded Solid | Solid |
Temp Rating | -14 Degrees to 90 Degrees C Dry |
Trade Designation | MC |
Voltage | 600 V |
Wire Color | Black/Blue/Green/Red/White |
Wire Size | 14 AWG |
Wire Size Wire and Cable | 14 AWG |
Wire and Cable Item | Metal Clad Armored Cable |