Description
Metal Clad Armored Cable, Trade Designation MC HCF, Wire Size 12 AWG, Number of Conductors 2 with Insulated CU Ground, Wire Color Black/Green/White, Jacket Color Green, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material Nylon, PVC, Nominal Outside Dia. 0.447 in, Packaging Coil, Voltage 600 V, Temp. Rating -14 Degrees to 90 Degrees C Dry
Specifications
Application | Indoor |
---|---|
Applications | ApplicationSouthwire HCF MCAPî Type MC Cable is suitable for use as follows:Branch-circuit wiring for patient care areas of hospitals, medical centers, and other health care facilities (when installed in accordance with NECî Articles 517 and 330, and mechanically protected per Article 300.4). Such areas include nursing homes, dental offices, clinics, and outpatient facilities. Use in hazardous anesthetizing areas is prohibited.Applications requiring redundant, dedicated or isolated grounding paths.Environmental air-handling spaces per NECî 300.22(C)Fished or embedded in plaster.Places of Assembly per NECî 518.4 and theaters per NECî 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NECî 645.5(D) & 645.5(D)(2).Use with UL Listed MCI-A fittings |
Cable Type Wire and Cable | HCF MC |
Conductor Design | Solid |
Construction | ConstructionSouthwire HCF MCAPî Type MC Cable is constructed with solid soft-drawn copper Type THHN circuit conductors (rated 90úC dry), redundant grounding provided by an armor assembly comprised of interlocked armor with a bare aluminum grounding/ bonding conductor, and a green insulated copper grounding conductor. The insulated circuit and grounding conductors are cabled together and wrapped with a binder tape bearing the print legend. The bare aluminum grounding/bonding conductor is located outside the binding tape and has the same lay as the insulated conductors. Green Aluminum interlocked armor is snugly wrapped around the conductor assembly. To insure proper cable termination, refer to the installation instructions provided with every reel and coil. |
Insulation Material | Nylon, PVC |
Insulation Thickness Mils | 15mils |
Item | Metal Clad Armored Cable |
Jacket Color | Green |
Jacket Material | Aluminum |
Jacket Material Wire and Cable | Aluminum |
Length | 250 ft |
Length Straight Wireway | 250 ft |
Max Amps | 20 |
No of Conductors | 2 |
No of Strands | 1 |
Nom Od Mils | 512mils |
Nominal Outside Dia | 0.447 in |
Number of Conductors | 2 with Ground |
Packaging | Coil |
Size Awg | 10 |
Size Awg or Kcmil | 12 AWG |
Spool Length | 250 ft. |
Standards | UL 83, 1063, 1569, NFPA 70, National Electrical Code, Federal Specification A-A59544 (Formerly J-C-30B), IEEE 1202, Vertical Cable Tray Flame Test, Listed for Use In UL 1, 2, and 3 Hour Through Penetration Firestop Systems |
Stranded Solid | Solid |
Temp Rating | -14 Degrees to 90 Degrees C Dry |
Trade Designation | MC HCF |
Voltage | 600 V |
Wire Color | Black/Green/White |
Wire Size | 12 AWG |
Wire Size Wire and Cable | 12 AWG |
Wire and Cable Item | Metal Clad Armored Cable |