Description
Metal Clad Armored Cable, Trade Designation MC ap, Wire Size 14 AWG, Number of Conductors 3 with Bare AL Ground, Wire Color Bare/Black/Red/White, Jacket Color Silver, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material Nylon, PVC, Nominal Outside Dia. 0.41 in, Packaging Coil, Voltage 600 V, Temp. Rating 194 Degrees F Dry
Specifications
Applications | ApplicationSouthwire MCAPî Type MC Cable - All Purpose is suitable for use as follows:Wherever standard AC or MC Cable is permitted.Branch circuit wiring in commercial, industrial, institutional, and multi-residential buildings.Fished or embedded in plaster.Concealed or exposed installations.Environmental air-handling spaces per NEC 300.22 (C).Places of Assembly per NEC 518.4 and theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).Use UL Listed Type MCI-A connectors |
---|---|
Cable Type Wire and Cable | MCap |
Conductor Design | Solid |
Construction | ConstructionSouthwire MCAPî Type MC Cable is constructed with solid soft-drawn copper Type THHN circuit conductors rated 90úC dry and a full-sized bare 8000 Series aluminum grounding/bonding conductor. This cable is available in sizes 14-8 AWG. The insulated conductors are cabled together and wrapped with a binder tape bearing the print legend. The bare aluminum grounding/bonding conductor is located outside the binding tape and has the same lay as the insulated conductors. Aluminum interlocking armor is snugly applied over the assembly. The aluminum armor and bare aluminum conductor are in intimate contact and together form the equipment ground path. To ensure proper installation, refer to the installation instructions provided with every reel and coil.An armor assembly that is an equipment grounding conductor per NEC 250.118(10)(b).Installation instructions included with every reel and coil.Simplified product application and installation over other armored products.Faster conductor make-up, wiring device installation and trim-out when grounding bonding conductor is terminated per installation instructions.Reduces installation costs up to 50% over pipe and wire.UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.Anti-short bushings are not required for use with MC cable per the NEC and UL |
Insulation Material | Nylon, PVC |
Insulation Thickness Mils | 15mils |
Item | Metal Clad Armored Cable |
Jacket Color | Silver |
Jacket Material | Aluminum |
Jacket Material Wire and Cable | Aluminum |
Length | 250 ft |
Length Straight Wireway | 250 ft |
Max Amps | 15 |
No of Conductors | 3 |
No of Strands | 1 |
Nom Od Mils | 471mils |
Nominal Outside Dia | 0.41 in |
Number of Conductors | 3 with Bare AL Ground |
Packaging | Coil |
Size Awg | 12 |
Size Awg or Kcmil | 14 AWG |
Spool Length | 250 ft. |
Standards | UL |
Stranded Solid | Solid |
Trade Designation | MC ap |
Voltage | 600 V |
Wire Color | Bare/Black/Red/White |
Wire Size | 14 AWG |
Wire Size Wire and Cable | 14 AWG |
Wire and Cable Item | Metal Clad Armored Cable |