Description
Metal Clad Armored Cable, Trade Designation MC FPLP, Wire Size 14 AWG, Number of Conductors 2 with Insulated CU Ground, Wire Color Black/Green/White, Jacket Color Red, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material PVC, Nominal Outside Dia. 0.439 in, Packaging Coil, Voltage 600 V, Temp. Rating -14 Degrees to 90 Degrees C Dry
Specifications
Application | Indoor |
---|---|
Applications | ApplicationRed Alertî Type MC-FPLP Cable is suitable for use as follows:Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devicesClass 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.Power, lighting, control, and signal circuits.Fished or embedded in plasterConcealed or exposed installations.Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). |
Cable Type Wire and Cable | MCFA |
Conductor Design | Solid |
Construction | ConstructionType TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The cable is dual rated as 90ðC dry, 600 Volt Type MC and 105ðC dry, 300 Volt Type FPLP cable. |
Insulation Material | PVC |
Insulation Thickness Mils | 15mils |
Item | Metal Clad Armored Cable |
Jacket Color | Red |
Jacket Material | Aluminum |
Jacket Material Wire and Cable | Aluminum |
Length | 250 ft |
Length Straight Wireway | 250 ft |
Max Amps | 15 |
No of Conductors | 2 |
No of Strands | 1 |
Nom Od Mils | 451mils |
Nominal Outside Dia | 0.439 in |
Number of Conductors | 2 with Ground |
Packaging | Coil |
Size Awg | 14 |
Size Awg or Kcmil | 14 AWG |
Spool Length | 250 ft. |
Standards | UL 83, 1063, 1424, 1569, NFPA 262-2002 Standard Method of Test for Flame and Smoke of Wire and Cables for Use In Air Handling Spaces, Federal Specification A-A59544 (Formerly J-C-30B), IEEE 1202, Vertical Cable Tray Flame Test, 2011 National Electrical Code, Approved for The State of Rhode Island Fire Systems, Listed for Use In UL 1, 2, and 3 Hour Through Penetration Firestop Systems, NFPA 70 (NEC) |
Stranded Solid | Solid |
Temp Rating | -14 Degrees to 90 Degrees C Dry |
Trade Designation | MC FPLP |
Voltage | 600 V |
Wire Color | Black/Green/White |
Wire Size | 14 AWG |
Wire Size Wire and Cable | 14 AWG |
Wire and Cable Item | Metal Clad Armored Cable |