Description
2 Strand OCC DX Series 900 Āµm Tight Buffered, Indoor/Outdoor Distribution, OFNR Riser, Multimode 62.5/125
Reference Previous Part Number:DX36-075K-ALS/900-OFNP
Note: This item may require 24 hours for cut and prep before shipping.Cable Charecteristics: D-Series Distribution Plenum Cables ("k" Jacket)
Tensile Load | Menimum Bend Radius | ||||||
Diameter | Weight | Installation | Operational | Installation | Long Term | ||
Fiber Count | Part Number | mm/(in) | kg/km (lbs/1,000) | N (lbs) | N (lbs) | cm (in) | cm (in) |
36 | DX036KALS9OP | 8.2 / (0.32) | 78 / (53) | 3000 / (670) | 1000 / (220) | 12.4 / (4.9) | 12.4 / (4.9) |
Applications
- Indoor/Outdoor tight-bound tight-buffered design allows cables to be installed in intra-building campus locations without costly transitions between cable types
- Ideal configuration for a single termination point reguiring multiple fibers
Features
- High performance components and construction
- High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls
- Helically stranded core for flexibility, survival in difficult installations, and mechanical protection for the fibers
- Lower installed cost
- High performance tight-buffered coating on each fiber for environmental and mechanical protection
- High crush resistance may eliminate the need for innerduct
- 900 Āµm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
- UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces
Indoor/Outdoor ("K" Jacket)
- Indoor/Outdoor plenum cables eliminate the need for costly cable transitions in different installation environments
- Cable materials are UV, water and fungus resistant
- Higher fiber counts available than similar cables available by others in subgrouped configuration
- Jacket is highly chemical resistant for installation in harsh industrial environments
- Interlocking armor can be applied to cables as an alternative to conduit installation
- Can be installed outside and in plenum or riser pathways inside, eliminating the need to transition cable types between environments
- 2 to 72 fiber configuration is smaller and lighter than comparable sub-grouped cables, which is ideal for installation in areas with limited space or tight bends
Mechanical and Environmental Performance
Indoor/Outdoor (K) | |
Operating Temperature | -40Ā°C to +85Ā°C |
Storage Temperature | -40Ā°C to +85Ā°C |
Installation Temperature (cable temp.) | -0Ā°C to +60Ā°C |
Flame Retardancy | UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Impact Resistance | 1,000 impacts |
Crush Resistance | 1,500 N/cm |
Flex Resistance | 1,000 Cycles |
Note:Optical Cable Corporation reserves the right to Change This specifications without prior notification.