Description
2 Strand OCC DX Series 900 µm Tight Buffered, Indoor/Outdoor Distribution, OFNP Plenum, OM3 Multimode 50/125
Reference Previous Part Number:BX02-060K-ALT/900-OFNP
Note: This item may require 24 hours for cut and prep before shipping.Cable Charecteristics: B-Series Breakout Plenum Cables (with 2.0mm subcables)
Tensile Load | Menimum Bend Radius | ||||||
Diameter | Weight | Installation | Operational | Installation | Long Term | ||
Fiber Count | Part Number | mm/(in) | kg/km (lbs/1,000) | N (lbs) | N (lbs) | cm (in) | cm (in) |
2 | BX002KALT9QP | 6.5 / (0.26) | 46 / (31) | 1600 / (360) | 400 / (90) | 9.8 / (3.9) | 9.8 / (3.9) |
Breakout Series Fiber Optic Cable Type OFNP plenum Product Specifications
Applications:
- Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are required
- Installed in ducts, plenums, and air handling spaces
- Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired
Features:
- High performance components and construction
- UL Listed in accordance with NEC sections 770.179(a) for use in ducts, plenums and air-handling spaces
- Most rugged and easy to install cable design for enterprise cabling applications
- Standard 2.0mm subcables can be directly terminated with standard connectors. 2.5mm and 2.9mm subcable sizes are also available
- Subcabled fiber is environmentally and mechanically protected
- Ideal for use in point-to-point runs in adverse environments
- Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
- Design is ideal for direct pulling with mesh grips
- Cable materials are Indoor/Outdoor - UV, water and fungus resistant
- Wide operating temperature range of -40°C to +85°C
- High performance 900 micron tight buffered coating on each optical fiber for environmental and mechanical protection
- Jacket highly chemical resistant for installation in harsh industrial environments
- Interlocking armor can be applied to cables as an alternative to conduit installation
- 2 to 60 fibers
Cost Savings:
- Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
- 900 µm eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber
- High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
Indoor/Outdoor (K) | |
Operating Temperature | -40°C to +85°C |
Storage Temperature | -40°C to +85°C |
Installation Temperature (cable temp.) | -0°C to +60°C |
Flame Retardancy | UL Listed Type OFNP (ANSI/NFPA 262) and FT6 (CSA C22.2 No. 232) |
Impact Resistance | 1,000 impacts |
Crush Resistance | 2,100 N/cm |
Flex Resistance | 2,000 Cycles |
Note: These specifications are subject to change without prior notification.