MTP®-F to MTP®-F APC Trunk Cable, OS2 Plenum Type A, 12 Fibers, TAA Compliant - Made in USA

No reviews yet Write a Review
$82.24 - $114.48
97403
2 MTP female connectors, green
12 fiber MTP connector, green
This ACA product is assembled in Palmer, MA, USA.
Polarity Type A wiring diagram (straight thru).
SKU:
97403
MPN:
MTP12SMP-F/F-A
Availability:
Ships in 3-5 days (even if expedited/overnight shipping is selected)
Current Stock:
Custom Lengths Available:
Click here
$82.24

Frequently Bought Together:

97403
Inc. Tax
Ex. Tax

Description

MTP® trunk cable is designed to provide high-density connections between network equipment in data centers which need space savings and reduced cable management troubles. With US Conec MTP® connectors and Corning MIC® 250 2.0 Cable, it is optimized for fiber optics direct connection and high-density data center applications such as high-bandwidth routers and high-density data clusters, and uses a simple push/pull latching mechanism for easy insertion and removal.

Specifications:

  • Made in the USA (Palmer, MA)
  • Connectors A & B: MTP® Female
  • Fiber Type: OS2 (single mode 9/125μm)
  • Wavelengths: 1310nm / 1383nm / 1550nm
  • Fiber Brand: Corning MIC® 250 2.0 Cable
  • Fiber Count: 12
  • Polish Type: APC
  • Jacket OD: 5.5mm
  • Jacket color: Yellow
  • Cable Rating: OFNP (Plenum)
  • Polarity: Type A
  • Minimum Bend Radius: 27.5mm
  • RoHS Compliant: Yes

Urgent order? Please contact: CustomerService@americancableassemblies.com

usconec-mtp-connector-panel.jpg

corning-mic250-2.0cable-panel.jpg

quality-assurance-program-panel.jpg

rocketpatch-packaging-panel.jpg

MPT®/MPO CONNECTOR POLARITY

Each MPT®/MPO connector has a key on one side of the connector body. The “Key Up” position refers to the orientation where the key is located at the top position of the connector. When looking at the end face of the connector, position 1 is on the far left while position 12 is on the far right. Depending on the adopted connectivity orientation, the MPO adapter needs to be suitable for its application, which is either “Key Up to Key Down” or “Key Up to Key Up”.

Method A:
Patch Cord Polarity Flip

The Patch Cord Polarity Flip, also known as the Transmit-Receive Flip, has fiber 1 in position 1 in the MPO connector at both ends of the patch cord and is maintained throughout the network. This method is the simplest design to install and maintain, as the orientation of the connector remains consistent.

Polarity Type A

Method B:
Adapter Polarity Flip

As stated in the name Adapter Polarity Flip, the polarity at one end of the connector is flipped. At one end of the connector fiber 1 is located at position 12 while fiber 12 is located at position 1. The connector orientation at the Transceiver and Receiver end are the same.

Polarity Type B

 

 

 

 