M12 plug, X-coded, IP67 Cat. 6A, field assembly, straight
Buy all together to create your own assemblies in the field.
All items are compatible.
- M12 Cat.6A X-coded plug based on IEC PAS 61076-2-109 and suitable for field assembly
- for a 8-wire M12 plug for AWG 22
- connection of AWG 26/1 - 22/1, AWG 26/7 - 22/7 possible
- solid copper wire diameter from 0.4 to 0.64 mm
- stranded copper wire diameter from 0.48 to 0.76 mm
- core diameter up to 1.6 mm
- cable jacket from 6.0 to 9.7 mm
- consists of only 2 parts
- easy assembly - connection without special tools
- zinc die-cast housing for industrial use
- suitable for applications in the railway industry according to data sheet
Resources
M12 plug, X-coded, IP67 Cat. 6A, field assembly, straight | MNF881A315-0001 |
View DataSheet |
Specifications
General Data
Electromagnetic measurement according to MICE: |
E2 |
Design: |
plug |
Shielding: |
shielded |
Transmission technology: |
Copper |
Dimension [Length] (mm): |
52 mm |
Dimension [Width] (mm): |
16.8 mm |
Dimension [Height] (mm]: |
16.8 mm |
Dimension [Length] (inch): |
2.047 in. |
Dimension [Width] (inch): |
0.661 in. |
Dimension [Height] (inch): |
0.661 in. |
Field assembly ability: |
yes |
Labeling option: |
on housing |
Transmission characteristics
Category (ISO): |
6A |
Category (TIA): |
6A |
Remote Powering: |
yes |
PoE: |
IEEE 802.3af |
PoE plus: |
IEEE 802.3at |
UPoE: |
yes |
HDBaseT: |
yes |
Transmission rate up to 10 GBit: |
IEEE 802.3an |
Connections/interfaces
Connector technology interface 1: |
IDC-connection |
Connector technology interface 2: |
M12-plug |
Coding interface 2: |
X-coded |
Number of ports interface 2: |
1 |
Number of ports interface 2 equipped: |
1 |
Number of positions/contacts interface 1: |
8 |
Number of positions/contacts interface 2: |
8 |
Conductor cross section solid wire [AWG] min-max: |
AWG 26/1 - AWG 22/1 |
Conductor cross section solid wire [mm²] min-max: |
0,128 - 0,324 mm² |
Conductor diameter solid wire [mm] min-max: |
0,409 - 0,643 mm |
Conductor diameter solid wire [inch] min-max: |
0,016 - 0,025 in. |
Conductor cross section stranded wire [AWG] min-max: |
AWG 26/7 - AWG 22/7 |
Conductor cross section stranded wire [mm²] min-max: |
0,141 - 0,355 mm² |
Conductor diameter stranded wire [mm] min-max: |
0,483 - 0,762 mm |
Conductor diameter stranded wire [inch] min-max: |
0,019 - 0,03 in. |
Core diameter (conductor with insulation) [mm min.]: |
0.85 mm |
Core diameter (conductor with insulation) [mm max.]: |
1.6 mm |
Core diameter (conductor with insulation) [inch min.]: |
0.033 in. |
Core diameter (conductor with insulation) [inch max.]: |
0.063 in. |
Cable sheath diameter [mm min.]: |
6 mm |
Cable sheath diameter [mm max.]: |
9.70 mm |
Cable sheath diameter [inch min.]: |
0.236 in. |
Cable sheath diameter [inch max.]: |
0.382 in. |
Cable access/outlet: |
straight M12 |
Electrical characteristics
Current carrying capacity: |
0.5 A |
Rated voltage: |
50 V AC / 60 V DC |
Through resistance: |
max. 5 mOhm |
Insulation resistance: |
min. 100 MOhm |
Dielectric strength conductor-conductor (primarily) [V DC]: |
500 V DC |
Mechanical data
Mounting method: |
screwable |
Insertion and withdrawal force: |
max. 30 N |
Life - Number of mating cycles: |
min. 100 |
Materials and material properties
Material - Housing: |
GD-Zn (zinc die-cast) |
Material - Contact: |
CuZnPb (brass) |
Material - Contact finish: |
Ni + Au (nickel-gold) |
Material - Shield: |
CuSn (tin bronze) |
Material - Shield finish: |
Sn (tin) |
Material - Stuffer cap: |
PA UL94-V0 |
Halogen free: |
yes |
Material - Finish: |
Ni (nickel) |
RoHS: |
compliant |
Environmental conditions
Temperature - Storage °C [min.]: |
-40 °C |
Temperature - Storage °C [max.]: |
85 °C |
Temperature - Storage °F [min.]: |
-40 °F |
Temperature - Storage °F [max.]: |
185 °F |
Temperature - Operating °C [min.]: |
-40 °C |
Temperature - Operating °C [max.]: |
85 °C |
Temperature - Operating °F [min.]: |
-40 °F |
Temperature - Operating °F [max.]: |
185 °F |
Particulate ingress: |
IP6X when plugged in |
Liquid ingress/immersion: |
IPX7 when plugged in |
Damp heat: |
25 °C / +40 °C / 93% RH // 5 cycles |
Overvoltage category [1]: |
III |
Degree of pollution [1]: |
2 |
Shock: |
490 m/s² |