M12 plug, D-coded, IP67 Cat. 5, Ø 6-9.7 mm, field assembly, straight
Buy all together to create your own assemblies in the field.
All items are compatible.
- field-attachable M12 plug, Cat.5, D-coded based on DIN EN 61076-2-101
- for a 4 wire cable connection
- connection of AWG 26/7 - 22/7, AWG 24/1 - 22/1 possible
- solid copper wire diameter from 0.4 to 0.64 mm
- stranded copper wire diameter from 0.48 to 0.76 mm
- conductor diameter up to 1.6 mm
- cable jacket from 6.0 to 9.7 mm
- consists of only 2 parts
- easy assembly - connection without special tools
- zinc die-cast housing for industrial use
- suitable for applications in the railway industry according to data sheet
Resources
| M12 plug, D-coded, IP67 Cat. 5, Ø 6-9.7 mm, field assembly, straight | MNF881A115 |
View DataSheet |
Specifications
General Data
| Electromagnetic measurement according to MICE: |
E2 |
| Design: |
plug |
| Shielding: |
shielded |
| Transmission technology: |
Copper |
| Dimension [Length] (mm): |
52 mm |
| Dimension [Width] (mm): |
16.8 mm |
| Dimension [Height] (mm]: |
16.8 mm |
| Dimension [Length] (inch): |
2.047 in. |
| Dimension [Width] (inch): |
0.661 in. |
| Dimension [Height] (inch): |
0.661 in. |
| Field assembly ability: |
yes |
| Labeling option: |
on housing |
Transmission characteristics
| Category (ISO): |
5 |
| Category (TIA): |
5 |
| Remote Powering: |
yes |
| PoE: |
IEEE 802.3af |
| PoE plus: |
IEEE 802.3at |
Connections/interfaces
| Connector technology interface 1: |
IDC-connection |
| Connector technology interface 2: |
M12-plug |
| Coding interface 2: |
D-coded |
| Number of ports interface 2: |
1 |
| Number of ports interface 2 equipped: |
1 |
| Number of positions/contacts interface 1: |
4 |
| Number of positions/contacts interface 2: |
4 |
| Conductor cross section solid wire [AWG] min-max: |
AWG 24/1 - AWG 22/1 |
| Conductor cross section solid wire [mm²] min-max: |
0,205 - 0,324 mm² |
| Conductor diameter solid wire [mm] min-max: |
0,511 - 0,643 mm |
| Conductor diameter solid wire [inch] min-max: |
0,02 - 0,025 in. |
| Conductor cross section stranded wire [AWG] min-max: |
AWG 26/7 - AWG 22/7 |
| Conductor cross section stranded wire [mm²] min-max: |
0,141 - 0,355 mm² |
| Conductor diameter stranded wire [mm] min-max: |
0,483 - 0,762 mm |
| Conductor diameter stranded wire [inch] min-max: |
0,019 - 0,03 in. |
| Core diameter (conductor with insulation) [mm min.]: |
0.85 mm |
| Core diameter (conductor with insulation) [mm max.]: |
1.6 mm |
| Core diameter (conductor with insulation) [inch min.]: |
0.033 in. |
| Core diameter (conductor with insulation) [inch max.]: |
0.063 in. |
| Cable sheath diameter [mm min.]: |
6 mm |
| Cable sheath diameter [mm max.]: |
9.70 |
| Cable sheath diameter [inch min.]: |
0.236 in. |
| Cable sheath diameter [inch max.]: |
0.382 |
| Cable access/outlet: |
straight M12 |
Electrical characteristics
| Current carrying capacity: |
max. 1 A |
| Insulation resistance: |
min. 100 MOhm |
Mechanical data
| Mounting method: |
screwable |
| Life - Number of mating cycles: |
min. 100 |
Materials and material properties
| Material - Housing: |
GD-Zn (zinc die-cast) |
| Material - Contact: |
CuZnPb (brass) |
| Material - Contact finish: |
Ni + Au (nickel-gold) |
| Material - Shield: |
CuSn (tin bronze) |
| Material - Shield finish: |
Sn (tin) |
| Material - Stuffer cap: |
PA UL94-V0 |
| Halogen free: |
yes |
| Material - Finish: |
Ni (nickel) |
| RoHS: |
compliant |
Environmental conditions
| Temperature - Storage °C [min.]: |
-40 °C |
| Temperature - Storage °C [max.]: |
85 °C |
| Temperature - Storage °F [min.]: |
-40 °F |
| Temperature - Storage °F [max.]: |
185 °F |
| Temperature - Operating °C [min.]: |
-40 °C |
| Temperature - Operating °C [max.]: |
85 °C |
| Temperature - Operating °F [min.]: |
-40 °F |
| Temperature - Operating °F [max.]: |
185 °F |
| Particulate ingress: |
IP6X when plugged in |
| Liquid ingress/immersion: |
IPX7 when plugged in |
| Particulate ingress interface 1: |
IP2X |
| Liquid ingress/immersion interface 1: |
IPX0 |
| Particulate ingress interface 2: |
IP6X when plugged in |
| Liquid ingress/immersion interface 2: |
IPX7 when plugged in |
| Damp heat: |
25 °C / +40 °C / 93% RH // 5 cycles |
| Overvoltage category [1]: |
III |
| Degree of pollution [1]: |
2 |
| Shock: |
490 m/s² |