The SAR4 and SAR5 can be connected to a telecommunications access line or separate control voltage source (AC/DC) and are activated by the call voltage or control voltage. The SAR reacts either only to the call voltage or to the control voltage. It activates an external signal emitter with its own or separate power supply (e.g. bell, horn, or lamp).
Resources
Specifications
General Data Operating voltage SAR4 | 230 V AC / 50 Hz |
Operating voltage SAR5 DC | 24 V DC / 10 mA |
Operating voltage SAR5 AC | 24 V AC / 10 mA |
Input / a/b telecommunications access line | |
Input / call voltage | 32 to 80 V AC |
Input / frequency range | 23 to 54 Hz |
Input / impedance | 10 kOhm at 75 V, 25 Hz |
Input / insertion loss | less than 0.5 dB |
Input / leakage resistance | more than 5 MOhm at 100 V |
Input / a/c external voltage | |
Input / control voltage DC | 5 to 40 V |
Input / control voltage AC | 5 to 40 V, 50 Hz |
Input / resistance | approx. 6 kOhm |
Output / switching current | max. 8 A |
Output / continuous current | max. 6 A |
Output / switching voltage | max. 250 V AC |
Output / switching capacity | 1500 VA (AC)30 W (less than 30 V DC)60 W (greater than 30 V DC) |
Call interval bridging | 0 to 12 s |
Limitation of power-on time | 0.25 to 12 s |
Electrical safety | acc. to EN 60950 |
Dimensions (W x H x D) | 35 x 69.3 x 60 mm |
Operating temperature range | -5 °C to + 55 °C |
Storage temperature range | -20 °C to + 70 °C |