Description
6 Strand, OCC BX Series Breakout, Indoor/Outdoor, OFNR Riser, Singlemode 9/125
Reference Previous Part Number:BX06-095D-SLX/900-OFNR
Note: This item may require 24 hours for cut and prep before shipping.CABLE CHARACTERISTICS: B-SERIES BREAKOUT RISER CABLES (WITH 2.5MM SUBCABLES)
Tensile Load | Menimum Bend Radius | ||||||
Diameter | Weight | Installation | Operational | Installation | Long Term | ||
Fiber Count | Part Number | mm/(in) | kg/km (lbs/1,000) | N (lbs) | N (lbs) | cm (in) | cm (in) |
6 | BX006DSLX9KR | 9.6 (0.38) | 84 (56) | 3,000 (670) | 1,200 (270) | 14.4 (5.7) | 9.6 (3.8) |
Applications
- Ideal for installations requiring an extremely rugged and reliable cable design where maximum mechanical and environmental protection are necessary
- Easiest cable to install where direct termination of connectors to sub-units and direct run to panels and equipment is desired
Features
- High performance components and construction
- UL Listed in accordance with NEC sections 770.179(b) for use in vertical runs in building riser shafts or from floor to floor
- Most rugged and easy to install cable design for enterprise cabling applications
- Core-Locked™ outer jacket design for installation survivability, long-term, trouble free service
- Ideal for use in long, vertical installations
- 2.5mm subcables can be direct-terminated with standard connectors (2.0mm and 2.9mm subcables also available)
- Subcabled fiber is environmentally and mechanically protected
- Ideal for use in point-to-point runs in adverse environments
- Direct termination to subcable provides additional strain relief for better connector retention during moves, adds, and changes
- Design is ideal for direct pulling with mesh grips
- Cable materials are Indoor/Outdoor UV, water and fungus resistant
- Wide operating temperature range of -40°C to +85°C
- High performance 900 µm tight-buffered coating on each optical fiber for environmental and mechanical protection
- Interlocking armor can be applied to cables as an alternative to conduit installation
Cost savings
- 900 µm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber. See page PI-6 for typical termination approach.
- Direct termination to subcable may eliminate the need for patch panels and patch cords and reduce connector loss
- High crush resistance may eliminate the need for innerduct
Mechanical and Environmental Performance
Indoor/Outdoor | |
Operating Temperature | -40°C to +85°C |
Storage Temperature | -55°C to +85°C |
Installation Temperature (cable temp.) | -10°C to +60°C |
Flame Retardancy | UL Listed Type OFNR (UL 1666) and FT4 (CSA C22.2 No. 232) |
Impact Resistance | 1,500 impacts |
Crush Resistance | 2,200 N/cm |
Flex Resistance | 2,000 Cycles |
Note: Optical Cable Corporation reserves the right to change this specification without prior notification.